Author:


Operating external environmental conditions:

Outside temperature: 0°C ~ 40°C

Relative humidity: £ 90% RH

External pressure: standard atmospheric pressure

Power supply: 380V ± 10%,50Hz + N + G

Cooling water temperature: ≤ +32°C

Grounding resistance: ≤ 4W

Cooling water pressure: 0.2-0.5MPa

Water flow: 22T/hour, interface G2 ″

Compressed air: 0.4-0.7MPa

Flow rate: 50L/min,

Interface: ø8

Main indicators of temperature

► Temperature range:-70°C/ 150°C

► Temperature deviation (in no-load steady state):≤ ± 2°C

► Temperature uniformity (at no-load steady state):≤ 2°C

► Temperature fluctuation (in steady state):≤ ± 0.5°C

► Temperature change rate (with 20kg load for aluminum block or with LCM sample):

Heating rate:(-40°C to 85°C) 5- 25°C/min (electric heating, linear average)

Cooling rate:( 85°C to -40°C) 5-25°C/min (mechanical refrigeration, linear average)

► Linear deviation: maximum ± 4.0 ℃ (deviation of temperature change rate)

Meet the GBT 5170.2-2008 environmental test equipment inspection method-temperature test equipment and GBT 5170.1-2008 electrical and electronic products environmental test equipment inspection method general

2. Linear deviation: 5 /-2 ℃/min,10 /-3 ℃/min,15 /-3 ℃/min, 20 /-4 ℃/min, 25 /-4 ℃/min

Heating time:-70 ℃ ~ +150 ℃ (80 *% in the whole process -7min of nonlinearity) When used as a common constant temperature and humidity box, the heating rate is 0~25 ℃/min

Cooling time: +150 ℃/RT ~-70 ℃ (80 *% temperature range in the whole process-nonlinearity is 7min) when used as a common constant temperature and humidity box, the cooling rate is 0~25 ℃/min

► Meet the following tests 

► Temperature overshoot: ≤ 4°C

Temperature stabilization time (the temperature reaches the set value and starts to calculate until it stabilizes within the set value ± 2°C):≤ 3min

Humidity range: 20% to 98% R.H.

► Humidity operating range: 20°C/ 85°C

► Humidity fluctuation (in steady state):≤ ± 2°C

► Humidity deviation (in steady state):± 3% RH

► The temperature and humidity detection system samples in seconds

It can meet the requirement that condensation is not allowed in the whole operation process.

► Temperature recovery time:<3min

► Test method:

1. The rate of temperature change shall be in accordance with IEC 60068-3-5.

2. The reference sensor is placed at the center point when it is unloaded, and at the air outlet when it is fully loaded.

3. The internal load during functional verification is: 20kg stability calibration point distribution map: 9 points according to JJF 1101-2003

Refrigeration system

► Refrigeration: Mechanical cooling is provided by a cascade system. It is realized by advanced two semi-sealed exchange type compressors. The body consists of a special cast iron, an easy-to-integrate cylinder and a piston of light metal alloy. water-cooled condenser

Compressor power: 2 × 44HP Germany BITZER semi-closed unit

► Cooling method: water cooling

► Refrigerant: Use environmentally friendly refrigerant R404A (excluding CFC), which is not prohibited by the Montreal Convention or the London Amendment and the new US EPA law.

Refrigeration patented technology: the ability to achieve intelligent adjustment of the cooling capacity, can be automatically adjusted with the temperature state, so as to quickly achieve temperature changes and temperature balance. Compared with the control temperature of ordinary cold and heat balance, the response speed is faster, the power consumption is lower, the temperature deviation and fluctuation in the box are smaller, and the temperature overshoot is effectively avoided. (See patent certificate for details)

Main features of box structure

► Heating system: high-efficiency nickel-chromium alloy electronic heater, completed by dual adjustable fault protection thermostat.

► Heating method: The heating wire is used to generate heat, and the hot air reaches the inside of the box evenly through the air duct. The air duct design has obtained the national patent, and the temperature state is adjusted intelligently through the software, so as to quickly realize the temperature change.

► Interior lighting: 1 x 35 W lamp with protective cover and control switch on the control panel outside the cabinet.

Bottom plate bearing: can be evenly bearing 100kg/㎡.

► Observation window: The single-wing door of the cabinet has a multi-glazed observation window with internal heating to prevent condensation and frost formation. The dimensions are mm 450 x 450.

► Door: Full opening single wing type with double silicone rubber seal and door lock.

Refrigeration system

► Refrigeration: Mechanical cooling is provided by a cascade system. It is realized by advanced two semi-sealed exchange type compressors. The body consists of a special cast iron, an easy-to-integrate cylinder and a piston of light metal alloy. water-cooled condenser

Compressor power: 2 × 44HP Germany BITZER semi-closed unit

► Cooling method: water cooling

► Refrigerant: Use environmentally friendly refrigerant R404A (excluding CFC), which is not prohibited by the Montreal Convention or the London Amendment and the new US EPA law.

Refrigeration patented technology: the ability to achieve intelligent adjustment of the cooling capacity, can be automatically adjusted with the temperature state, so as to quickly achieve temperature changes and temperature balance. Compared with the control temperature of ordinary cold and heat balance, the response speed is faster, the power consumption is lower, the temperature deviation and fluctuation in the box are smaller, and the temperature overshoot is effectively avoided. (See patent certificate for details)

Previous

Next

Latest Solution

2026-10-21

Why You Should Never Use Tap Water In A Constant Temperature And Humidity Test Water Tank

When conducting temperature and humidity experiments in a test chamber, the water required is generally supplied by a dedicated water tank. If the water quality is unclean, will it have any impact on the test chamber? What are the standards for the water used in a test chamber? Will it have any impact if ordinary tap water is used?

2026-08-05

Custom Programmable Temperature Impact Test Chamber for Sale

Temperature impact test (temperature impact test of surge water) is to simulate the load situation of surge water generated when the components are driven through the accumulated water, so as to ensure the functional stability of the components under the condition of rapid cooling due to water. If the vehicle is driving on a watery road in winter, ice water splashes onto a hot system/component, the failure mode is mechanical rupture of the material or seal failure due to different temperature expansion coefficients. (This test is not a corrosion test)

2026-08-05

Hydrogen fuel cell explosion-proof plateau climate chamber

The equipment is equipped with the air discharge pipeline pressure control system of the new energy engine system (the control range is normal pressure ~ 60KPa, the control accuracy is 2KPa, the maximum emission is about 308 g/S (about 924 m/h)), and the hydrogen discharge pipeline pressure control system (the control range is normal pressure ~ 60KPa, the control accuracy is 2KPa, and the maximum emission is about 80 g/min (about 5.3 m/h))).

2026-08-05

2021 - 08 Walk-in battery pack test box

The active protection and passive protection of the test chamber have multiple unique protection designs, which can prevent and reduce the leakage, explosion and other accidents that may occur during the development of the battery.

2026-08-05

Walk-in compound salt spray test chamber (stainless steel box)

Walk-in compound salt spray chamber, meeting the requirements of GJB150.11A-2009 military equipment laboratory environmental test methods part 11: salt spray test; GB/T10125-1997 artificial atmosphere corrosion test salt spray test, etc.

2026-08-05

Rapid temperature change three comprehensive test chamber (damp heat, with vertical vibration table)

Heating/cooling rate: (rapidly changing temperature range:-55 ℃ ~ 125 ℃)