05

2026

-

Custom Programmable Temperature Impact Test Chamber for Sale

Author:


Temperature impact test (temperature impact test of surge water) is to simulate the load situation of surge water generated when the components are driven through the accumulated water, so as to ensure the functional stability of the components under the condition of rapid cooling due to water. If the vehicle is driving on a watery road in winter, ice water splashes onto a hot system/component, the failure mode is mechanical rupture of the material or seal failure due to different temperature expansion coefficients. (This test is not a corrosion test)

Reference Standard

ISO16750-4-2010 road vehicles. Environmental conditions and tests for electrical and electronic equipment

VW80000:2009 Volkswagen electrical and electronic components test methods

Schematic Diagram of Surge Nozzle Structure

surge nozzle

Basic parameters

1. Volume in the box: 1000L

2. Water temperature: 0~4 ℃

3. Temperature in test chamber: RT 10~180 ℃

4. Spraying distance: 300~350mm

5. Number of nozzles: 3

6. Ice water flow: about 3 ~ 4L/each surge/each nozzle

7. Spray time: 3s, adjustable

8. Conversion time:<20s

9. Test cycle times: 100 times, adjustable

10. Total cycle time: 30 minutes, adjustable

11. Water tank volume: about 60L

Schematic of Water Splash Test Device

Ice water impact test

Requirements

1. No water infiltration

2. The test piece is only allowed to open after completing the entire test sequence.

3. The function of the test piece before, during and after the test must be intact, and all parameters must be within the scope of technical requirements.

high temperature heating system

1. Heating rate: ≥ 2 ℃/min (no load, average over the whole process)

2. Temperature deviation: ≤ ± 5.0 ℃

3. Temperature fluctuation: ≤ 1.0 ℃

4. Heater: high quality stainless steel electric heater. (Non-contact solid state relay control)

5. Temperature control: PT100 temperature sensor, solid state relay, circulating fan, over-temperature protector, etc.

Previous

Next

Previous

Next

Latest Solution

2026-10-21

Why You Should Never Use Tap Water In A Constant Temperature And Humidity Test Water Tank

When conducting temperature and humidity experiments in a test chamber, the water required is generally supplied by a dedicated water tank. If the water quality is unclean, will it have any impact on the test chamber? What are the standards for the water used in a test chamber? Will it have any impact if ordinary tap water is used?

2026-08-05

Custom Programmable Temperature Impact Test Chamber for Sale

Temperature impact test (temperature impact test of surge water) is to simulate the load situation of surge water generated when the components are driven through the accumulated water, so as to ensure the functional stability of the components under the condition of rapid cooling due to water. If the vehicle is driving on a watery road in winter, ice water splashes onto a hot system/component, the failure mode is mechanical rupture of the material or seal failure due to different temperature expansion coefficients. (This test is not a corrosion test)

2026-08-05

Hydrogen fuel cell explosion-proof plateau climate chamber

The equipment is equipped with the air discharge pipeline pressure control system of the new energy engine system (the control range is normal pressure ~ 60KPa, the control accuracy is 2KPa, the maximum emission is about 308 g/S (about 924 m/h)), and the hydrogen discharge pipeline pressure control system (the control range is normal pressure ~ 60KPa, the control accuracy is 2KPa, and the maximum emission is about 80 g/min (about 5.3 m/h))).

2026-08-05

2021 - 08 Walk-in battery pack test box

The active protection and passive protection of the test chamber have multiple unique protection designs, which can prevent and reduce the leakage, explosion and other accidents that may occur during the development of the battery.

2026-08-05

Walk-in compound salt spray test chamber (stainless steel box)

Walk-in compound salt spray chamber, meeting the requirements of GJB150.11A-2009 military equipment laboratory environmental test methods part 11: salt spray test; GB/T10125-1997 artificial atmosphere corrosion test salt spray test, etc.

2026-08-05

Rapid temperature change three comprehensive test chamber (damp heat, with vertical vibration table)

Heating/cooling rate: (rapidly changing temperature range:-55 ℃ ~ 125 ℃)