Daily maintenance tips for high and low temperature test chambers and high and low temperature alternating test chambers
Author:
1.High and low temperature test chambers are generally quite high.We recommend placing them in a relatively benign temperature environment.Our empirical temperature range is 8℃to 23℃.For laboratories that do not have this condition,appropriate air conditioners or cooling towers must be equipped.
2.Must adhere to professional management personnel,conditional units shall not assign personnel to the supplier factory training learning on a regular basis.To acquire more professional experience and capabilities in maintenance and repair.
3.Fixed to be cleaned once every 3 months:Condenser for compressor adopts air cooling,cooling fan should be regularly maintenance condenser for decontamination dust removal to ensure the good ventilation and heat exchange performance:For compressors cooled by water,in addition to ensuring the inlet water pressure and temperature,it is also necessary to guarantee the corresponding flow rate,and regularly clean and descale the interior of the condenser to obtain its continuous heat exchange performance.

4.Regularly clean the evaporator:Due to the varying cleanliness levels of the test samples,a lot of dust and other small particles will accumulate on the evaporator under the effect of forced air circulation.Regular cleaning is necessary.www.shuangyitest.com
5.Circular blades,condenser fan clean and balance:similar to clean the evaporator due to different work environment test chamber,circular blades and condenser fan will condense a lot of dust particles such as object,should be cleaned on a regular basis.
6.Water and clean humidifier:if water not free,humidifier scaling easy cause humidifier dry,may damage the humidifier,so you have to clean water and humidifier on a regular basis.
7.After each test,keep the temperature close to the ambient temperature,let it work for about 30 minutes,then cut off the power supply and wipe the inner walls of the working chamber clean.
8.If equipment need to move under the guidance of the best in macro exhibition company technical personnel,so as not to cause unnecessary injury or damage to the equipment.
9.Stop for a long time when not in use should be regularly every half moon to product electricity,electricity time not less than 1 hour.

10.Maintenance Principles:
Since the high and low temperature test chamber is basically composed of multiple systems such as electrical,refrigeration and mechanical,once the equipment malfunctions,a comprehensive inspection and analysis of the entire equipment system should be carried out.
Generally speaking,the process of analysis and judgment can start from the"outside"and then move to the"inside",that is,first eliminate external factors,and then conduct a system decomposition of the equipment based on the fault phenomenon,followed by a comprehensive analysis and judgment of the system.Or,the backward reasoning method can be adopted to find the cause of the fault:First,check if there is a problem with the electrical system according to the electrical wiring diagram.Finally,check if it is a problem with the refrigeration system.Before the cause of the fault is clarified,do not disassemble or replace parts at will to avoid unnecessary trouble.