The two-zone thermal shock chamber of Shuangyi manufactures can be switched and transferred between high and low temperature chambers. It is controlled by a suspended basket for movement, with a short conversion time that meets national standard requirements. The temperature recovery time is short, and the temperature change speed is fast. The overall structure of the equipment is compact and the volume is small. The two-chamber method is adopted, which improves the temperature uniformity in the working chamber.
The Easy-maintainable two-zone thermal shock chamber can be used to test the extent to which material structures or composite materials can withstand continuous environments of extremely high and low temperatures in an instant, thereby testing the chemical changes or physical damage caused by thermal expansion and contraction in the shortest time. The applicable objects include materials such as metals, plastics, rubbers, and electronics, which can be used as the basis or reference for product improvement.
I.Core Performance and Technical Parameters
|
Temperature range |
-70℃ ~ +200℃(Customizable expansion) |
|
Transfer time |
≤8s(International standard ASTMD618) |
|
Temperature stability |
±0.5(Unloaded) |
|
Tank structure |
The high-temperature tank and the low-temperature tank are independent dual circulation systems. |
|
Up to standard |
IEC 60068-2-14,MIL-STD-883J |
1. Performance and Function
(1) Complete the full-stroke impact from -55℃ to +150℃ within 15 seconds.
(2) The throttle switch technology patent (patent number: ZL2018 2, 0749896.7).
(3) The optional liquid nitrogen temperature mode (-196 ℃).
2. Production raw materials
(1) The tank: military grade stainless steel SUS304 (corrosion resistant coating).
(2) Insulation: high pressure polyurethane foam (0.02 W/m or less thermal conductivity, K).
(3) Sealing strip: silicone rubber + fluoro dragon double-layer structure (temperature tolerance - 100 ℃ ~ 300 ℃).
3.Customer base because of buying two-zone thermal shock chamber from Shuangyi supplier
|
Electron component |
Chip /PCB/ connector manufacturer |
|
Auto industry |
New energy battery/sensor supplier |
|
Scientific research institution |
Materials Laboratory/Aerospace Components Testing Center. |
|
Industry application scenarios: Automotive electronics→Reliability testing of automotive-grade ics. Military aerospace→Environmental adaptability verification of airborne equipment. Consumer electronics→Thermal fatigue test for mobile phone motherboards. |
|
II. The core purpose on Advanced two-zone thermal shock chamber
(1) The material heat bilges cold shrink coefficient analysis.
(2) Solder joint cracking/coating spalling failure simulation.
(3) The product temperature limit cycle life test and verify.
III. Technological breakthroughs
(1) Germany EBM centrifugal fan, air volume 12 m3 / min) or higher.
(2) The multistage PID algorithm ± 0.1 C.
(3) Dynamic compensation loT remote monitoring (supports MODBUS/Profibus protocol).
IV. The core point
(1) Military level reliability: hit 30000 consecutive no attenuation (third party CNAS report).
(2) The optimization of energy consumption 30% : double groove design than traditional single heat storage box power saving a third.
(3) Intelligence prevent condensation: automatic humidity control module to avoid the sample frost (optional).
(4) The modular maintenance: compressor/heater design, quick release down time reduced by 80%.
V. Issues of concern to customers
|
Question |
Professional answers |
|
Impact of test interruption |
The backup power supply can maintain operation for 30 minutes (optional). |
|
Sample capacity |
Two standard trays (compatible with JEDEC standard carriers) |
|
Data traceability |
21CFR Part11 Electronic Record Compliance |
|
Calibrating period |
The self-diagnosis system prompts maintenance nodes |
|
Site requirements |
Three-phase 380V/50Hz, minimum floor space 1.2m×0.8m |
VI. The simplified version of the instructions in two-zone thermal shock chamber 1 Year and a half Warranty
1. Sample loading tray to use high temperature resistant layer.
2. The program Settings - > touch screen setting temperature dwell time (ex: - 40 ℃ * 125 ℃ for 30 min ↔ * 30 min).
3. Safety protection - > open automatically locks the driving function.
4. Data export - > USB directly generating PDF report (including temperature curve).

Keywords
Further details


Team Highlights
Guangzhou Jiaoguang Asia Exhibition
Guangzhou Jiaoguang Asia Exhibition
Shanghai Munich Exhibition
Company Qualifications
Two-Zone Thermal Shock Chamber
Contact Information
Category