The core principle and purpose of PCT testing:
PCT testing accelerates the process of moisture penetrating into the product interior through external protective materials or along the interface between materials and metals by creating an environment that is far stricter than conventional constant temperature and humidity testing. This can quickly identify defects in materials, processes and designs.
Objective:
To evaluate the moisture-proof reliability of the product, assess the quality of packaging materials, and evaluate the failure modes that cause short circuits or corrosion in the circuit.
The main criteria for PCT testing:
JEDEC standard (the most commonly used in the field of electronic components)
JESD22-A102: "High-Pressure Cooking Test". This is the most core and universal standard. It specifies in detail the test conditions, equipment requirements, test procedures and result reports.
Common conditions: 110°C / 121°C, 85%RH / 100%RH, 1.1 atm / 1.2 atm / 2.0 atm, with time ranging from 24 hours to several hundred hours.
JESD22-A110: "High Acceleration Temperature and Humidity Stress Testing". It is also often referred to, especially for solid-state surface mount devices in non-airtight packages.
IEC 60068-2-66: "Environmental Testing - Part 2-66: Testing methods - testing Cx: Steady-state, wet heat, unsaturated pressurized steam". This is an internationally recognized basic environmental testing standard, which is highly consistent with the JEDEC standard in terms of principle and conditions.
MIL-STD-883: "Test Methods and Procedures for Microelectronic Devices”, Method 1004: Moisture resistance. Although the use of military standards has decreased in some fields, their strictness still serves as a reference for high-reliability products.
GB/T 2423.87: Environmental testing - Part 2: Test methods - Test Cx: Steady-state, wet heat, unsaturated pressurized steam. This is basically equivalent to adopting the Chinese national standard IEC 60068-2-66.
High-pressure accelerated aging test chamber:
The core is a sealed cavity capable of withstanding high pressure.
It is equipped with an accurate temperature, humidity and pressure control system.
It is usually equipped with a pure water or deionized water supply system to prevent scale and pollution.
Test Conditions:
The selection of test conditions depends on the reliability requirement level of the product. Common combinations are as follows:
| Temperature | Relative humidity | Pressure(Gauge pressure) | Test standard | Remark |
| 110℃ | 85%RH | ~0.9atm | JESD22-A102 | One of the standard conditions |
| 121℃ | 100%RH | ~1.2atm | JESD22-A102, IEC 60068-2-66 | Most commonly used conditions |
| 130℃ | 85%RH | ~1.7atm | JESD22-A102 | More stringent conditons |
| 110℃ | 85%RH | ~0.9atm | JESD22-A110(HAST) | Unsaturated HAST |
PCT High Pressure Accelerated Aging Test Chamber
Product Usage:
This equipment is mainly composed of a box body, a heating system, an air circulation system and a control system. The outer shell of the box is made of cold-rolled steel plate with electrostatic powder coating or matte stainless steel, and the inner liner is made of high-quality mirror-finish stainless steel plate. The overall appearance is elegant and generous. The insulation layer is made of hard polyurethane foam and a small amount of superfine glass wool, featuring high strength and excellent insulation performance. The main temperature controller of this equipment adopts an intelligent digital display temperature controller. It features a humanized operation method, which is easy to learn and use. Moreover, the operation of instruments of different functional grades is compatible with each other. The input adopts a digital correction system, with built-in nonlinear correction tables for commonly used thermocouples and thermal resistors, ensuring precise and stable measurement. It features position adjustment and AI artificial intelligence adjustment functions, with a 0.2-level accuracy and multiple alarm modes. Supports historical data record query, USB flash drive export and backup function. The pressure gauge adopts high-temperature resistant steam pointer pressure gauge, ensuring accurate pressure measurement.
|
Inside idimensions |
PCT-40:350mm x L500 mm (Circular test chamber) |
|
|
Performance index |
Temperature & humidity range |
+100 ℃ ~ +135℃ (Saturated steam temperature), 100% Steam humidity |
![]() |
||
|
Temperature fluctuation |
±0.5℃ |
|
|
Humidity uniformity |
3%RH |
|
|
Pressurization time |
0.00 Kg~1.04 Kg / cm2 about 45min |
|
|
Temp. Display accuracy |
0.1℃ |
|
|
Pressure fluctuation |
±0.02Kg |
|
|
emperature and humidity operation control system |
Controller |
Imported LCD digital display PID + SSR. Micro PLC + Color touch screen. |
|
Accuracy range |
Setting accuracy: Temperature±0.1℃; Indication accuracy: Temperature±0.1℃, Resolution:±0.1℃ |
|
|
Temperature sensor |
Platinum resistor PT100Ω |
|
|
Heating system |
Fully independent system, nickel-chromium alloy electric heating type heater |
|
|
Circulatory system |
Steam convection heat dissipation type |
|
|
Used Materials |
Exterior material |
High-quality carbon steel plate. Phosphating electrostatic powder coating treatment /SUS304 stainless steel matte line textured treatment. |
|
Interior material |
SUS316 high-quality stainless steel |
|
|
Insulation material |
Polyurethane rigid foam, superfine glass fiber cotton |
|
|
Standard parts |
Sample rack *1pcs, Partition layer*2pcs |
|
|
Safety protection |
Overpressure, short circuit, over temperature, over current protections |
|
|
Power supply |
AC 1phase 220V/ 50±0.5Hz |
|