The 2 Layers High Low Temperature Humidity Test Chamber, with its innovative dual-chamber independent control design, has solved the pain points of low efficiency and large space occupation of traditional single-chamber equipment, and has become the core equipment for modern laboratories to improve testing efficiency.
I.Product Overview and Technical Highlights
The China double-layer high low temperature humidity test chamber factory adopts an upper and lower independent test chamber structure. Each chamber is equipped with a completely independent refrigeration, heating, control and circulation system, which can simultaneously carry out test tasks under two different temperature and humidity conditions, greatly improving the equipment utilization rate and experimental efficiency.
1.Core performance index
|
Parameters |
Testing conditions |
|
Temperature range |
-70℃~+150℃, cover the demands of extreme cold and hot environment. |
|
Humidity range |
10%~98%RH (Some models can be expanded to 5%RH). |
|
Temperature uniformity |
≤±2℃(Empty load) |
|
Temperature fluctuation |
≤±0.5℃ |
|
Heating rate |
≥3℃/min (At +20℃ to +150℃) |
|
Cooling rate |
≥1℃/min (At +20℃ to -70℃) |
2. Breakthrough design window:
(1) Double independent system: two sets of complete separation of refrigeration and control system, the mutual interference.
(2) The energy saving technology: adopt refrigeration and heating, heating refrigeration not "intelligent logic, energy consumption reduced by 30%.
(3) Explosion-proof safety pressure mouth + automatic fire extinguishing devices, explosion-proof chain triple protection.
(4) Intelligent control: 7 "touch screen, support 9999 procedures section circulating set, support USB/RS232 data export.
II.Core Technologies and Structural Design
1. Precision temperature and humidity control system
Adopting two-stage compression refrigeration technology (French Tecumseh hermetic compressor), combined with PID intelligent algorithm and SSR solid-state relay temperature control, 2 Layers High Low Temperature Humidity Test Chamber achieves a temperature accuracy of ±0.1°C. The humidity control adopts dual modes of steam humidification and ultrasonic atomization, combined with platinum resistance sensors, to achieve a humidity control accuracy of ±1%RH.
2. Sturdy and durable box structure
|
Item |
Material |
|
Interior chamber material |
SUS304 stainless steel mirror plate, corrosion-resistant and easy to clean. |
|
Exterior chamber material |
1.2mm cold-rolled steel plate with anti-static spraying or 304 stainless steel brushed plate. |
|
Insulating layer |
With 100mm thick high strength PU foam, glass fiber cotton composite material has 30% improvement in heat insulation performance. |
|
Seal system |
Double layers high and low temperature resistant silicone rubber sealing strips ensure long-term air-tightness. |
|
Visual window |
Electric heating demisting tempered glass and inner protective net (explosion proof design). |
3. The intelligent security protection system
(1) Compressor state real time monitoring, start the interval of 15 minutes or more protection.
(2) The leakage/overload/over-heat/water/compressor overvoltage multiple protection.
(3) Independent explosion-proof pressure, reduce internal stress.
(4) Can be equipped with automatic fire extinguishing system (for battery and other dangerous goods testing).
III. Application Industries and Typical Customer Groups
The lab double-layer high low temperature humidity test chamber serves industries with strict requirements for environmental reliability and meets the testing requirements of international standards such as GB/T, IEC, and MIL. The industry distribution and test scenarios are as follows:
|
Industry |
Test sample |
Test purpose |
Reference standard |
|
Electronics |
Mobile phone/Chip/PCB |
Signal stability and moisture-proof performance in high-temperature and high-humidity environments. |
GB/T 2423.3, IEC 60068 |
|
Auto parts |
Automotive electronics/batteries/seals |
Verification of low-temperature performance in cold-resistant zones and high-temperature and high-humidity performance in tropical zones. |
GJB 150, DIN 75200 |
|
New energy |
Power batteries/energy storage cells |
Charge and discharge performance, thermal runaway safety test. |
UL 1642, GB 31241 |
|
Aerospace |
Airborne equipment/aerospace materials |
Verification of adaptability to high-altitude low-temperature and high-humidity environments. |
MIL-STD-810, RTCA DO-160 |
|
Medical apparatus & instruments |
Implant materials/electronic devices |
Functional stability test under temperature and humidity changes. |
ISO 13485, USP <1079> |
IV. Product Advantages and Solutions
Efficiency improvement plan
1. Space saving: A single machine only occupies 60% of the space of two traditional devices. Parallel:
2. The test run at the same time two kinds of test conditions (such as A cavity 85 ° C / 85% RH, B cavity to 40℃).
3. Rapid temperature change: the Taiwan high-speed heating + shunt blast electric heating tube, the heating rate of 3℃ / min.
Cost optimization scheme
1. The energy consumption: intelligent power management than 30% energy saving equipment at the same level.
2. Maintenance convenient: waterway subdivision circuit design, the side door open maintenance.
3. Long life design: compressor delay protection + anti-corrosion components, extend the life of the core parts.
V. Key Issues of Greatest Concern to Customers
Q1: Does the double-layer design affect the performance of the single-chamber?
A1: Double cavity completely independent refrigeration system and a control module, work independently, performance parameters and the same volume of single cavity equipment completely consistent, there is no attenuation performance.
Q2: Equipment can meet the requirements of lithium battery explosion?
A2: Provide security enhancements suite, including explosion-proof pressure release, stainless steel fence, door explosion-proof chain, automatic fire extinguishing device is optional.
Q3: How to choose different volume models?
A3: standard reference model configuration is as follows:
|
Model |
Inner size |
Outer size |
Temperature range |
Weight |
Application scene |
|
PY-H80L |
W40*H50*D40cm |
W65*H155*D110cm |
-70℃~+150℃ |
200kg |
Small electronic components |
|
PY-H225L |
W50*H75*D60cm |
W85*H180*D145cm |
-40℃~+150℃ |
400kg |
Auto Sensors |
|
PY-H408L |
W60*H85*D80cm |
W105*H190*D155cm |
-70℃~+150℃ |
450kg |
Power battery module |
|
PY-H1000L |
W100*H100*D100cm |
W125*H215*D195cm |
-70℃~+150℃ |
600kg |
Aerospace equipment components |
Note: The 80-225L is suitable for component testing. A capacity of over 400L meets the requirements for whole machine/module testing.
Q4: What are the key points of daily equipment maintenance?
A4: three core maintenance points:
|
1.Compressor maintenance: Use a stabilized power supply and have a start-up interval of more than 15 minutes. |
|
2. Water quality management: Pure water with a resistivity of ≥500Ω · m is recommended for humidification. |
|
3. Condenser cleaning: Use compressed air for dust removal every month (increase the frequency in dusty environments). |
VI. Operating Instructions
|
1. Installation requirements 1). Venue:Horizontal (ground tilt≤5 mm/m), well ventilated. 2). The temperature and humidity: 5 ~ 30℃, environment temperature humidity 85% RH or less. 3). Power supply: AC380V±10%, 50Hz (large volume models), independent grounding. 4). Spacing: Reserve at least 80cm of maintenance space around the equipment. |
|
2. The operation process 1)Sample: sample weight 25 kg/layer (uniform distribution) 2)Parameter Settings: (1) through the touch screen to set temperature and humidity curve (2) support programming 3 x 1200 period of the 120 units. 3.Safety monitoring: 1). Make sure pressure flow 2). Check the water level alarm function 4. Data export: Export historical data in CSV format via USB connection. |
|
5. Maintain daily: 1)Check the water level, clean the face. 2)A month, humidifying water tank cleaning, check the door seal. 3)Quarterly:Calibration temperature and humidity sensor (suggest) by professionals. 4)A year:Replace the frozen oil, comprehensive stress testing. |
2 Layers High Low Temperature Humidity Test Chamber offers an affordable price. This device supports customization on demand. If you need to know about special temperature ranges (-90 to 200℃), explosion-proof enhanced types or remote monitoring solutions, please contact our technical team to obtain customized solutions.
Technology endless, reliability verification has never been so efficient, make each product can stand the test of extreme conditions.

Keywords
Further details


Team Highlights
Guangzhou Jiaoguang Asia Exhibition
Guangzhou Jiaoguang Asia Exhibition
Shanghai Munich Exhibition
Company Qualifications
2 Layers High Low Temperature Humidity Test Chamber
Contact Information
Category